MODULation OFF

MODULation EXT

Query
Syntax: MODULation?
Response: OFF

|

AM INT |

AM EXT |

FM INT |

FM EXT


DEPTh

This command sets the AM modulation depth in %

Arguments
Type:

Numeric

Units:

none (implied %)

Range:

0 to 100

Rounding:

To integer

Command Type: Setting or Query
Setting
Syntax:

DEPTh<ws><percent depth>

DEPTh<ws>MINimum|MAXimum

Examples:

DEPTh 50

Query
Syntax:

DEPTh?[<ws>MINimum|MAXimum]

Response:

NR3



MODFRequency