power-on default settings. Table 3-2 lists the factory default settings. You can program the waveform generator for any
settings you want at power on, as described earlier in section 3.6.6.

Note: OUTPUT status saved into memory cannot be recalled for power-on setting. This is a safety feature to prevent
sensitive devices connected to the generator from being damaged if user accidentally turns on the unit.

Table 3-2

Power-on Default Settings

Key Functions

Values

Comments

FREQUENCY

1.00000000 KHz

Wave frequency

RATE(ARB)

1 µs

Sample time per point

AMPLITUDE

5.00 V

Peak to peak output amplitude

FUNCTION

SINE

Output waveform

OFFSET

0.00 V

Zero offset

REPETITION

10 ms

Internal trigger rate

MODE

CONT

Waveform mode

N-BURST

2

Waves per burst

START ADRS

1

Start memory address

WAVELENGTH

1000

Number of points per waveform

TRIG SOURCE

EXT

External trigger source

OUTPUT

OFF

Output disabled

SWEEP

OFF

Sweep execution

MODULATION

OFF

Modulation execution


3.11 Memory


The waveform generator uses a non-volatile FLASH memory for storing arbitrary waveform data and front panel
settings. Up to 400,000 points Arbitrary waveform and 50 front panel settings are stored. These front panel settings
can be used to store starting address and lengths of many different waveforms stored in memory as reference points for
quick recall.

Because it is impossible to guarantee 100% of the time against loss of stored data, you should maintain a record of the
data stored in memory so that you can manually restore such data, if necessary.




3.12 Displaying Errors

At power-on, the waveform generator performs a diagnostic routine to check itself for problems. If the diagnostic

routine finds an error, an error message is displayed. The waveform generator also displays error messages when front-

panel settings are either invalid or may produce unexpected results.

Error messages for Model 4075and 4078

Message Text

Cause

Out of range

Attempt to set variable out of instrument limits.