Syntax:

[:SOURce]:FUNCtion[:SHAPe]?

Examples:

:FUNC?

Response:

SIN|TRI|SQU|ARB|PUL

Considerations:


The following functions are available:


Sinusoid, Square, TRIangle, ARBitrary, PULse


4.13.1.6 Point Rate


:SOURce:PRATe <point rate>


This command is used to set the point rate. It is coupled with the frequency of the waveform by the relation


Frequency = 1/(Point Rate * Wavelength)


Thus changing the point rate will result in a change in frequency.
Arguments
Type:

Numeric

Units:

S, mS, uS, nS

Range:

10nS to 100S

Rounding:

To 4 digits

Command Type: Setting or Query
Setting
Syntax:

:SOURce:PRATe<ws><point rate>[units]

:SOURce:PRATe<ws>MINimum|MAXimum

Examples:

:ARB:PRAT 500NS

Query
Syntax:

:ARBitrary:PRATe?[<ws>MINimum|MAXimum]

Response:

NR3

4.13.1.7 AM modulation

The following sections control the AM modulation:

4.13.1.7.1 AM STATe

This command activates or deactivates AM modulation:
Arguments

Type:

Boolean

Command Type: Setting or Query
Setting
Syntax:

[: SOURce:]AM [:STATe]<ws>ON|1|OFF|0

Examples:

: SOURce:AM :STAT ON

AM OFF

Query
Syntax:

[:SOURce:]AM[:STATe]?

Response:

0|1

4.13.1.7.2 AM DEPTh

This command sets the AM modulation depth in %

Arguments
Type:

Numeric

Units:

none (implied %)

Range:

0 to 100