1 trigger mode, 2 trigger source, 3 burst count – B&K Precision 4078 - Manual User Manual

Page 69

Advertising
background image

:SOURce <MANual|INTernal|EXTernal|BUS

:TIMer <numeric value>


Note: For model 4078, nothing changes in the commands above to control channel 1. But for channel 2, change

:TRIG to :TRIG2. For example, to change channel 2 mode to gate, send the command: TRIG2:MODE
GATE.



4.13.3.1 Trigger Mode


:TRIGger:MODE <trigger mode>


This command is used to set the trigger mode. It is not a standard SCPI command.

Arguments
Type:

Character

Options:

CONTinuous

TRIGger

GATE

BURSt

Command Type: Setting or Query
Setting
Syntax:

:TRIGger:MODE<ws><option>

Examples:

:TRIG:MODE CONT

:TRIG:MODE BURS

Query
Syntax:

:TRIGger:MODE?

Response:

CONT|TRIG|GATE|BURS

4.13.3.2 Trigger Source


:TRIGger:SOURce <trigger source>


This command is used to select the trigger source, for use in the Trigger, Gate and Burst trigger modes.

Arguments
Type:

Character

Options:

MANual - Front panel MAN key

BUS - GPIB trigger (GET or *TRG)

INTernal - Internal trigger

EXTernal - External trigger

Command Type: Setting or Query
Setting
Syntax:

:TRIGger:SOURce<ws><option>

Examples:

:TRIG:SOUR BUS

:TRIG:SOUR INT

Query
Syntax:

:TRIGger:SOURce?

Response:

MAN|BUS|INT|EXT

4.13.3.3 Burst Count


:TRIGger:BURSt <burst count>


Used to set the number of cycles to be output in the BURST mode. It is not a standard SCPI command.

Advertising