4.13.1.9.2 FSK LOWFrequency


This command sets the lower of the two frequencies used in FSK modulation.

Arguments
Type:

Numeric.

Units:

MHz, KHz, Hz (default)

Range:

The whole frequency range of the current function.

Rounding:

The value is rounded to 4 digits.

Command Type: Setting or Query
Setting
Syntax:

[:SOURce:]FSK:LOWFrequency<ws><frequency>[units]

[:SOURce:]FSK:LOWFrequency<ws>MINimum|MAXimum

Examples:

FSK:LOWFrequency 5KHZ

FSK:LOWF 5E3

FSK:LOWF MAXIMUM

FSK:LOWF MIN

Query
Syntax:

[:SOURce:]FSK:LOWFrequency?[<ws>MAXimum|MINimum]

Examples:

FSK:LOWF?

FSK:LOWF? MAX

Response:

NR3

4.13.1.9.3 FSK HIFrequency


This command sets the higher of the two frequencies used in FSK modulation.
Arguments
Type:

Numeric.

Units:

MHz, KHz, Hz (default)

Range:

The whole frequency range of the current function.

Rounding:

The value is rounded to 4 digits.

Command Type: Setting or Query
Setting
Syntax:

[:SOURce:]FSK:HIFrequency<ws><frequency>[units]

[:SOURce:]FSK:HIFrequency<ws>MINimum|MAXimum

Examples:

FSK:HIFrequency 5KHZ

FSK:HIF 5E3

FSK:HIF MAXIMUM

FSK:HIF MIN

Query
Syntax:

[:SOURce:]FSK:HIFrequency?[<ws>MAXimum|MINimum]

Examples:

FSK:HIF?

FSK:HIF? MAX

Response:

NR3


4.13.1.9.4 FSK RATE

This command sets the rate of switching between the two frequencies of the modulation.
Arguments
Type:

Numeric.

Units:

MHz, KHz, Hz (default)

Range:

Fmax = 1MHz

Fmin = 0.01Hz

Rounding:

The value is rounded to 4 digits.

Command Type: Setting or Query
Setting
Syntax:

[:SOURce:]:FSK:RATE<ws><frequency>[units]

[:SOURce:]:FSK:RATE <ws>MINimum|MAXimum