3.2

Main parts

1

Fan

2

Evaporator

3

Expansion valve

4

Solenoid valve for defrosting

5

Regulation

6

temperature sensor

7

Impressed current anode

8

Safety thermostat

9

Steatite electrical resistor

10

temperature sensor

11

Air conduits

12

High pressure (HP) pressure switch

13

Low pressure (LP) pressure switch

14

Compressor

15

Pressure measurement point - High pressure (HP)

16

Ventilation grid

17

Domestic hot water outlet

18

Condenser

19

Cold water inlet

3.3

Operating principle

The thermodynamic DHW tank uses unheated ambient air or outside

air to prepare DHW.
The refrigerant circuit is a closed circuit in which the R-134a

refrigerant plays the role of an energy carrier.
The heat from the intake air is transferred to the refrigerant in the

finned heat exchanger at a low evaporation temperature.
The refrigerant is sucked in by a compressor in vapour form, which

raises it to a higher pressure and temperature and sends it to the

condenser. In the condenser, the heat extracted in the evaporator and

some of the energy absorbed by the compressor are released into

the water.

C003185-F

5

6

10

2

1

3

4

15

16

13

12

14

17

11

19

18

8

7

9