5.1.3.

Browsing in the menus

1. Press the MENU key. The SE nS 1 menu is displayed

(Temperature measurement).

2. Use the ( and ) keys to scroll through the menus (See table

below).

3. To access the selected menu, press the MODE key (B).
4. To go back to the previous display, press the key MENU.
5. To go back ty the main display, press once key MENU.

Accessing the menu Menu

Description

See chapter

1x MENU

SE nS
1

Measurements menu

¼ "Reading out measured values", page 47

1x )

CL OC
2

Setting the time and the date

¼Refer to the user instructions

2x )

Pr oG
3

Modify an hourly programme

¼Refer to the user instructions

3x )

Co un
4

Meters

¼ "Counters", page 47

4x )

PA rA
5

Setting parameters

¼ "Reading out measured values", page 47

5x )

Er bL
6

Failure history

¼ "Message and error history", page 62

6x )

Co dE
7

Installer parameters

¼ "Modifying the installer parameters", page 49

5.2

Check points before commissioning

4

Check that the thermodynamic DHW tank is full of water.

4

Check the seals.

4

Check that the safety devices are operating correctly.

4

Check the operating mode.