Checking / solution

B26

The bottom DHW temperature sensor is

open

Bad connection

4

Check whether the sensor is connected

4

Check the link and the connectors

4

Check that the sensor has been correctly fitted

Sensor fault

4

Check the Ohmic value of the sensor

4

Replace the sensor if necessary

B27

The top DHW temperature sensor is short

circuited

Bad connection

4

Check whether the sensor is connected

4

Check the link and the connectors

4

Check that the sensor has been correctly fitted

Sensor fault

4

Check the Ohmic value of the sensor

4

Replace the sensor if necessary

B28

The top DHW temperature sensor is open Bad connection

4

Check whether the sensor is connected

4

Check the link and the connectors

4

Check that the sensor has been correctly fitted

Sensor fault

4

Check the Ohmic value of the sensor

4

Replace the sensor if necessary

B32

The impressed current anode is in open

circuit.

4

Check that the connection cable between the SCU PCB and the

anode is not severed

4

Check that the anode is not broken

4

Check that the DHW tank is correctly filled with water

Remarks:

4

Domestic hot water production has stopped but can nonetheless
be restarted using key V (For 72 hours)

4

Protection against corrosion is not ensured

B33

The impressed current anode is short-

circuited.

4

Check that the connection cable between the PCU PCB and the

anode is not short-circuited

4

Check that the anode is not short-circuited

Remarks:

4

Domestic hot water production has stopped but can nonetheless
be restarted using key V (For 72 hours)

4

Protection against corrosion is not ensured

B40

Measurement error on the domestic hot

water temperature sensors.

Remarks:

4

This message is only displayed on initial

commissioning.

4

This message disappears after 10
minutes or when you press the B key.

The 3 sensors do not measure the same value

4

Check the location of the sensors.

If the causes of the problem are still present after several attempts at

automatic start-up, the appliance goes into lockdown mode (also

called failure).
¼see chapter: "Messages (type code EXX)", page 61

8. Troubleshooting