11 filling the thermodynamic dhw tank – DE DIETRICH KALIKO TWH 200E - TWH 300E - TWH 300EH User Manual

Page 44

Advertising
background image

*

Earth

L

Live

N

Neutral

P

Pressure switch

R1 - R6

Relay

S4

Evaporator sensor

S5

Room sensor

SPL1

Splice

TA

Impressed current anode

TS

Safety thermostat

X1

Connecting the impressed current anode

X2-S3

Bottom DHW temperature sensor

X3-S2

Middle DHW temperature sensor

X4-S1

Top DHW temperature sensor

X5

Room sensor, Evaporator, Pressure switch

X6

Control panel connection

X7

Hydraulic back-up command terminal board

X8

Command terminal board

X-B1

Electrical back-up command terminal board

X-HC

Pricing information input (HP-HC).

Allows authorisation of domestic hot water production

depending on the setting of the HP/HC input

4.11 Filling the thermodynamic DHW tank

1. Open a hot water tap.
2. Open the cold water tap located on the safety unit. Ensure that the

drainage valve on the unit is closed.

3. When the water overflows through the hot water tap, the appliance

is full. Close the hot water tap.

C

0

0

3

4

0

9

-A

4. Installation

TWH 200E TWH 300E TWH 300EH

42

03/02/2014 - 300026515-001-03

Advertising