Connection with timer programming and photovoltaic, Signal – DE DIETRICH KALIKO TWH 200E - TWH 300E - TWH 300EH User Manual
Page 42
Advertising
4.9.6.
Connection with timer programming and
photovoltaic signal
3
AC type differential switch
4
Circuit breaker
5
Photovoltaic panel
6
Inverter
A
Power cable 1,5 mm
2
4
The heat pump and electrical
backup are allowed to operate
depending on the time program.
4
The heat pump will start to heat
at the temperature of 62 °C
(parameter P07) when the
photovoltaic signal is actif.
4
If the photovoltaic signal is actif
when the contact is open, set
the parameter P04 on 3.
4
If the photovoltaic signal is actif
when the contact is closed, set
the parameter P04 on 4.
C004218-B
A
TEST
16 A
40 A
2 A
30
mA
L
N
X11-2 HP/H
PV-S
DC
AC
X11-1 LINE
C
3
5
6
4
4
4. Installation
TWH 200E TWH 300E TWH 300EH
40
03/02/2014 - 300026515-001-03
Advertising