N dhw production mode indicator, N indicator of the water volume available – DE DIETRICH KALIKO TWH 200E - TWH 300E - TWH 300EH User Manual

Page 46

Advertising
background image

M + W

Boost function active via the HP/HC inlet

% + W

Boost function active via the HP/HC inlet

> C
+ W

Boost function active via the HP/HC inlet

n DHW production mode indicator

The main display indicates the domestic hot water production mode.

Display Domestic hot water

production

Description

C003487-B

Heat pump

The 2 segments of the tank flash simultaneously when domestic hot water production

is handled by the heat pump

C003484-B

Electrical back-up

The right-hand segment of the tank flashes when domestic hot water production is

handled by electrical back-up

C003485-B

Hydraulic additional heating The left-hand segment of the tank flashes when domestic hot water production is

handled by hydraulic back-up (Version EH)

C003486-A

Heat pump + Electrical back-

up + Hydraulic additional

heating

The 2 segments of the tank flash alternately when domestic hot water production is

handled by the heat pump, by electrical back-up and by hydraulic backup (EH version)

n Indicator of the water volume available

When producing domestic hot water, the display indicates the number

of baths available and the level to which the tank is filled (quantity of

hot water available).

4

The number of baths is calcuated based on a domestic hot water

temperature of 40°C.

4

The level to which the tank is filled is calculated according to the

set point temperature.

4

Set the 2 parameters, P18 and P19, according to the

appliance model.
¼See chapter: "Modifying the installer parameters", page

49

C003493-A

1

4

3

4

1

2

5. Commissioning

TWH 200E TWH 300E TWH 300EH

44

03/02/2014 - 300026515-001-03

Advertising