V > 30m – DE DIETRICH KALIKO TWH 200E - TWH 300E - TWH 300EH User Manual

Page 23

Advertising
background image

Cupboard:

4

With EH77 or EH273: 1100 mm x 1100 mm - Ducted version. Be

sure to make the aeraulic connections absolutely leakproof in

order to prevent the cupboard from losing heat.

We strongly recommend installing the control system in the

living room.

4

With EH434 (Reduced elbow kit): 800 mm x 800 mm - Ducted

version. Be sure to make the aeraulic connections absolutely

leakproof in order to prevent the cupboard from losing heat.

We strongly recommend installing the control system in the

living room.

TWH 200E TWH 300E TWH 300EH

A (mm) 1690

2000

2000

4

To ensure adequate access and facilitate maintenance, allow

sufficient space around the appliance.

4

Model 200: Allow a minimum distance of 0.4 m at both sides of the

appliance and a minimum room height of around 1.84 m for

operation without air ducts.

4

Model 300: Allow a minimum distance of 0.4 m at both sides of the

appliance and a minimum room height of around 2.15 m for

operation without air ducts.

C

0

0

3

4

8

1

-C

69

0

30

0

1100

1100 mini

0 160

C004734-A

0 160

/ 200

800 mini

800

82

6

59

8

C003188-F

V > 30m

3

15

0

15

0

mi

n.

40

0

mi

n.

40

0

69

0

A

0

60

0

TWH 200E TWH 300E TWH 300EH

4. Installation

03/02/2014 - 300026515-001-03

21