Message and error history, 2 message and error history – DE DIETRICH KALIKO TWH 200E - TWH 300E - TWH 300EH User Manual

Page 64

Advertising
background image

Code no. Description

Checking / solution

E06

The evaporator temperature sensor is short

circuited

Note: DHW production is handled by back-up if

back-up enabled

Bad connection

4

Check whether the sensor is connected

4

Check the link and the connectors

4

Check that the sensor has been correctly fitted

Sensor fault

4

Check the Ohmic value of the sensor

4

Replace the sensor if necessary

E07

The evaporator temperature sensor is open

Note: DHW production is handled by back-up if

back-up enabled

Bad connection

4

Check whether the sensor is connected

4

Check the link and the connectors

4

Check that the sensor has been correctly fitted

Sensor fault

4

Check the Ohmic value of the sensor

4

Replace the sensor if necessary

E08

Malfunction on the defrosting function

Note: DHW production is handled by back-up if

back-up enabled

4

Check activation of the defrosting solenoid valve

4

Check the position of the temperature sensor in the evaporator

4

Check that the fan is working correctly

4

Check that the condensates can flow freely

E09

The low pressure pressure switch alarm

sounds for more than 120 seconds

Note: DHW production is handled by back-up if

back-up enabled

4

Check the position of the temperature sensor in the evaporator

4

Check that the fan is working correctly

4

Check that the condensates can flow freely

E10

The low pressure pressure switch alarm has

been tripped more than 3 times during the last

24 hours

Note: DHW production is handled by back-up if

back-up enabled

4

Check the position of the temperature sensor in the evaporator

4

Check that the fan is working correctly

4

Check that the condensates can flow freely

4

Check the refrigerant load

8.2

Message and error history

The Er bL 6 menu is used to consult the last 16 messages and the

last 16 errors displayed by the control panel.
1. Press once the MENU key. The SE nS 1 menu is displayed.
2. Press the ) key 5 times. The Er bL 6 menu is displayed.

3. Press the MODE B key to go to this menu.

Accessing the menu Menu Description
1x
)

Err

Error history

2x )

bL

Blockage history

3x )

CLr

Reset error and blockage history

C003203-D

1x

3

1

4

3

4

1

2

MENU

MODE

C004189-A

1

4

3

4

1

2

MENU

MODE

8. Troubleshooting

TWH 200E TWH 300E TWH 300EH

62

03/02/2014 - 300026515-001-03

Advertising