Maintenance operations to be performed, Refrigerant circuit, Hydraulic circuit – DE DIETRICH KALIKO TWH 200E - TWH 300E - TWH 300EH User Manual

Page 57: Aeraulics, Impressed current anode, Checking the safety valve or unit, 2 maintenance operations to be performed

Advertising
background image

7.2

Maintenance operations to be performed

7.2.1.

Refrigerant circuit

No maintenance is required on the refrigerant circuit in the

thermodynamic water heater.

7.2.2.

Hydraulic circuit

Check the watertightness of the water connections.

7.2.3.

Aeraulics

n Cleaning the evaporator

DANGER

Risk of injury on the sharp-edged fins.

CAUTION

Do not distort or damage the fins.

4

Clean the evaporator at regular intervals using a soft-haired brush.

4

Carefully realign the fins using a suitable comb if they are bent.

n Cleaning the fan

Check the cleanliness of the fan 1 time per year. Clogging by dust

and other particles impairs the heat pump’s performance.

7.2.4.

Impressed current anode

No maintenance operations are required on an impressed current

anode.

The appliance’s control panel must be switched on to

ensure operation of the impressed current anode.

7.2.5.

Checking the safety valve or unit

Operate the safety valve or unit at least 1 time per month to check

that it is running correctly. This check provides forewarning of any

occurrences of excess pressure that may damage the domestic hot

water calorifier.

TWH 200E TWH 300E TWH 300EH

7. Checking and maintenance

03/02/2014 - 300026515-001-03

55