8 Troubleshooting

8.1

Messages (Code type bxx or Exx)

8.1.1.

Messages (type code

bXX)

In the case of failure, the control panel displays a message and a

corresponding code.
1. Make a note of the code displayed.

The code is important for the correct and rapid diagnosis of the

type of failure and for any technical assistance that may be

needed.

2. Disconnect and reconnect the mains cable.

The appliance will restart only when the malfunction has been

corrected.

3. If the code is displayed again, correct the problem by following the

instructions in the table below:

Code no. Description

Checking / solution

B00

Parameter error on the PCU PCB

Reset the parameters

B01

Pressure switch alarm

Note: DHW production is handled by back-

up if back-up enabled

4

Check the power supply to the compressor

4

Check the pressure switch connection

B02

Maximum DHW temperature exceeded

Note: DHW production is not covered (by the

compressor or the back-up)

4

Check the connection on the top DHW sensor

4

Check that the back-up is not running permanently

B03

The room temperature is higher than 35°C.

The compressor is outside its operating

range.

Note: DHW production is handled by back-

up if back-up enabled.

4

Modify the parameters according to the instructions in the manual.

4

The compressor will handle DHW production once the room

temperature is less than 35°C.

B04

The room temperature is less than -5°C.

Note: DHW production is handled by back-

up if back-up enabled.

4

Modify the parameters according to the instructions in the manual.

4

The compressor will handle DHW production once the room

temperature is higher than -5°C.

B25

The bottom DHW temperature sensor is

short circuited

Bad connection

4

Check whether the sensor is connected

4

Check the link and the connectors

4

Check that the sensor has been correctly fitted

Sensor fault

4

Check the Ohmic value of the sensor

4

Replace the sensor if necessary

TWH 200E TWH 300E TWH 300EH

8. Troubleshooting

03/02/2014 - 300026515-001-03

59