H (125 mm) and identification „r – Burkert Type 2012 User Manual

Page 16

Advertising
background image

16

Replacingthesealset

Type 2000, 2002, 2012

6.2

change the packing gland for valves with actuator
size f (80 mm), G (100 mm), h (125 mm) and
identification „R“

Danger!

Risk of injury from discharge of medium and release of pressure!

▶ Before removing a device, switch off the pressure and vent the lines!

the seal set for the packing gland contains:

item

description

item

description

13, 14

7 Chevron seal

7

1 Spindle guide

Upper chevron seal
Upper pressure ring

Pressure spring

Lower pressure ring

Lower chevron seal

Spindle guide

Pushing direction

for packing gland parts

Figure 3:

Pushing direction for packing gland parts

Warning!

Risk of injury if the wrong tools are used!

▶ To remove the actuator from the valve body, use an open-end wrench, never a pipe wrench.

▶ To replace the packing gland, use a special installation wrench (see Kapitel “8”).

▶ Observe tightening torques!

note!

Before the packing gland can be replaced, the actuator must be removed from the valve body and the swivel
plate removed.

procedure:

Clamp the valve body

1

into a holding device (applies only to valves not yet installed).

note!

damage to the seat contour!

▶ When removing the actuator, ensure that the valve is in the open position.

for control function a: pressurize the lower control air connection with compressed air (5 bar): Valve opens.

english

Advertising