Burkert Type 2012 User Manual

Page 25

Advertising
background image

25

Conversionofcontrolfunction

Type 2000, 2002, 2012

7.5

conversion from flow below the seat to flow
above the seat

Danger!

danger – high pressure!

▶ Turn off the pressure and vent the lines before loosening lines or valves.

Risk of injury from improper maintenance!

▶ Maintenance may be performed by authorized technicians only!

▶ To screw on or unscrew valve body or actuator, use an open-end wrench, never a pipe wrench.

▶ Observe tightening torques.

Required parts:

item

description

28, 29

2 Pressure springs for actuator C (40 mm), D (50 mm), E (63

mm), F (80 mm)

procedure:

Mount valve

1

on the body.

Caution!

danger through taut springs!

▶ Carefully open piston actuator!

Release cover

31

with special wrench until the springs are completely relaxed, holding up the actuator body

12

against the hexagon.

For information about the special wrench, see Chapter “8. Installation tools”.

Remove and / or insert pressure springs

28

29

depending on actuator.

for actuator size c (40 mm), d (50 mm), e (63 mm) and f (80 mm): Remove pressure springs and insert
new, weaker springs.

for actuator size G (100 mm) and h (125 mm): Remove outer spring only

29

inner spring

28

remains in

the actuator.

Mount cover

31

and screw tightly with special wrench.

Check the valve for function and leaks.

Note changed direction of flow and changed pressure range!

english

Advertising
This manual is related to the following products: