Section 1 specifications – Hach-Lange AMTAX indoor sc User Manual

Page 5

Advertising
background image

5

Section 1

Specifications

Specifications are subject to change without notice.

Enclosure rating

AMTAX sc: IP55
AMTAX indoor sc: IP54

Enclosure material

ASA/PC UV-resistant

Measuring method

GSE (Gas-Sensitive Electrode)

Measuring range

0.02 to 5.0 mg/L NH

4

–N

0.05 to 20 mg/L NH

4

–N

1 to 100 mg/L NH

4

–N

10 to 1000 mg/L NH

4

–N

Detection limit

0.02 mg/L NH4–N (0.02 to 5.0 mg/L NH

4

–N Measuring Range)

0.05 mg/L NH

4

–N (0.05 to 20 mg/L NH

4

–N Measuring Range)

1 mg/L NH

4

–N (1 to 100 mg/L NH

4

–N Measuring Range)

10 mg/L NH

4

–N (10 to 1000 mg/L NH

4

–N Measuring Range)

Measuring accuracy
(with standard solution)

≤ 1 mg/L: 3 % + 0.02 mg/L
>1 mg/L: 5 % + 0.02 (0.02 to 5.0 mg/L NH

4

-N Measuring Range)

3 % + 0.05 mg/L (0.05 to 20 mg/L NH

4

–N Measuring Range)

3 % + 1.0 mg/L (1 to 100 mg/L NH

4

–N Measuring Range)

4.5 % + 10 mg/L (10 to 1000 mg/L NH

4

–N Measuring Range)

Repeatability
(with standard solution)

3 % + 0.02 mg/L NH

4

–N (0.02 to 5.0 mg/L NH

4

–N Measuring Range)

2 % + 0.05 mg/L (0.05 to 20 mg/L NH

4

–N Measuring Range)

2 % + 1.0 mg/L (1 to 100 mg/L NH

4

–N Measuring Range)

2 % + 10 mg/L (10 to 1000 mg/L NH

4

–N Measuring Range)

Response time (90 %)

Measuring Range: 0.02 to 5 mg/L NH

4

–N

0.02 to 0.2 mg/L NH

4

–N: 3 measurements (shortest 15 minutes)

0.2 to 5 mg/L NH

4

–N: 1 measurement (5 minutes)

Measuring Ranges: 0.05 to 20 mg/L; 1 to 100 mg/L and 10 to 1000 mg/L NH

4

–N

< 5 minutes

Adjustable measuring interval

5 to 120 minutes

Power supply

Power supply with power cable only using the sc1000 controller
(analyzer, Filter Probe sc and drain tubing: 115 V versions or 230 V versions)

Data transmission

Data transmission with data cable on the sc1000 controller

Electrical power consumption

500 VA

Electrical fuse protection

Via sc1000 controller
Maximum of 2 analysis instruments for each sc1000 controller.

Outputs

Relay, current outputs, bus interface via sc1000 controller

Operating temperature

AMTAX sc: –20 to 45 °C (–4 to 113 °F); 95 % relative humidity, non-condensing
AMTAX indoor sc: 5 to 40 °C (41 to 104 °F); 95 % relative humidity, non-condensing

Storage temperature

–20 to 60 °C (–4 to 140 °F); 95 % relative humidity, non-condensing
4 to 55 °C (39 to 131 °F); 95 % relative humidity, non-condensing (electrode)

Sample temperature

4 to 40 °C (39 to 104 °F)

Sample pressure

With continuous sample preparation –30 mbar to +50 mbar at overflow vessel

Sample flow

Range: 1.0 L/h–20.0 L/h

Sample quality

Ultra filtrated or

comparable

Sample level

Level of liquid in basin with filtration probe must be below analyzer