General information – Hach-Lange RTC113 ST-Module User Manual
Page 12
Advertising

12
General information
Abbildung 2
Base module RTC 100-240 V version
Note: All components are pre-wired.
1
L(+)
7
Automatic circuit breaker (ON/OFF switch for item 10
and 11 without fuse function).
2
N(–)
8
sc 1000 connection: RS485 (CX1010-N041)
3
Input AC 100–240 V / Input DC 95 V–250 V
9
Battery compartment
4
PE (protective earth)
10 CPU base module,
consisting of Ethernet port with
battery compartment (CX1010-N000), CPU module with
CF card (CX1010-0021) and passive aeration element.
5
24 V transformer (Specification
section 3.1.1, page 17
)
11
Power supply module, consisting of bus coupler
(CX1100-0002) and terminal module 24V.
6
Output DC 24 V, 0,75 A
Advertising
This manual is related to the following products: