Configure disk drives, Rebuilding arrays, Configure disk drives rebuilding arrays – Adaptec 48300 User Manual

Page 53

Advertising
background image

Using the Adaptec RAID Configuration Utility

53

Configure Disk Drives

Caution:

If the drive is used in an array, you may not be able to use

the array again. Do not configure a drive that is part of a boot array.
To determine which disks are associated with a particular array, see

Viewing Array Properties on page 51

.

You will not be able to configure the drive if there is a legacy
partition table or valid Master boot record (MBR) already existing.
You will need to run a disk partitioning software like Fdisk to delete
the partition.

To configure drives:

1

From the Main menu, select Configure Drives.

2

Use the up and down arrow keys to highlight the disk you wish to
configure, then press Insert.

3

Repeat

Step 2

if you want to add another drive to be configured.

4

Press Enter.

5

Read the warning message and ensure that you have selected the
correct disk drives to configure. Type Y to continue.

Rebuilding Arrays

Note:

Rebuilding applies to Fault Tolerant arrays (RAID 1 and

RAID 10) only. If a spare does not exist and a disk drive fails, you need
to create a spare before you can rebuild an array. See

Adding/Deleting

Hotspares on page 52

before continuing your Rebuild.

By replacing a failed drive of a RAID 1 array with a new drive, you can
Rebuild to get the array to Optimal status and assume fault tolerance.
You can perform a Rebuild in the following ways:

!

Advertising