Using the Adaptec RAID Configuration Utility

54

System Shutdown Rebuild

Note:

This section applies only when an operating system and drivers

are installed.

You can shut down the system and replace the failed drive with a new
one (of equal or greater capacity). When the system is booted, you can
assign the new drive as a spare, and this will start the Rebuild task. All
the data from the good drive is copied to the new one, and the original
RAID 1 array is recreated.

Manual Rebuild

1

From the Main Menu, select Manage Arrays. From the List of
Arrays, select the array you want to Rebuild.

2

Press Ctrl+R to Rebuild.

Verifying Arrays

If you are notified of a mismatch of data during a RAID 1 build, follow
these steps to verify the arrays:

Note:

The Verify option is available only if the array is Optimal. If the

array has failed, you must rebuild the array.

1

Highlight the array you want to verify.

2

Press Ctrl+S.

3

When the Verify is complete, you are notified of any errors found
during the Verify operation.