Aerobell 168 - Installation

LN-9270-12.3

34

INSTALLATION (continued)

HIGH VOLTAGE CABLE ASSEM-
BLIES

General Instructions

1. When routing cable, ensure that no chaff-
ing, binding, or pulling on the cable will occur.
Maintain at least a 4-inch (100mm) bend radi-
us. When possible, sleeve cable with the ap-
propriate sized tubing for external cable pro-
tection. Torsion stress should be minimized.

2. Considerations should be taken when rout-
ing cables next to other cabling and fluid tub-
ing. Be cognizant of the placement of such
cable near control wires and fluid lines. Follow
NEC wiring standards where applicable. Sep-
aration of AC, control wiring, and fluid tubing is
advisable.

3. To ensure that all cable connections are
clean and free of foreign materials, wipe with
Naphtha. This also applies to the cascade,
splitter, and applicator connectors.

4. Apply dielectric grease (LSCH0009-08) on
all cable end connectors (cascade, splitter,
and applicator) to displace any encapsulated
air.

5. Each time a cable is replaced, the nut as-
sembly (78441-00) must also be replaced.

6. Ensure that no conductive sponges are
used in any connector!

7. A10560-XX cables are not to be modified in
the field. To do so will void any and all war-
ranties that may exist.

There are two (2) high voltage cable assem-
blies available:

A10560-XX is a shielded cable and is the
most flexible. It is available in several lengths
per the "Accessories" chart in the "Parts Iden-
tification" section.

79006-XX is a metallic core conductor cable
with a polyethylene jacket and an exterior
PTFE sleeve. It comes pre-assembled with
banana jacks at each end.

A third option is to build your own cable to a
specific length not to exceed 100-ft. (30.5 me-
ters) in length. A non-shielded metallic con-
ductor cable (SSW-1064) is used. the end
user must install the EPS-4245 banana jacks.
It is highly recommended that an insulating
jacket (79007-00) be installed over the as-
sembly to protect it from damage.

Voltage Master 2 (78789) Cable
Installation

The Voltage Master 2 contains a control pan-
el and a power supply (LEPS5001). To install
the high voltage cable, loosen the nut on the
top of the LEPS5001-02 power supply tank
and insert the high voltage cable through the
nut and rubber grommet and push into tank
until the banana jack is fully seated. Tighten
the nut firmly by hand to grip the cable.

To connect multiple applicators, you can con-
nect a high voltage cable from LEPS5001-02
tank to the input of a LEPS5000-05 junction
tank. Up to five (5) applicators can be sup-
plied from the junction tank. High voltage ca-
ble connection on this tank is the same as the
Voltage Master 2 tank.

HIGH VOLTAGE CABLE
CONFIGURATIONS