Aerobell 168 - Introduction

LN-9270-12.3

86

MAINTENANCE DISASSEMBLY PROCEDURES

(For Robot/Machine Mount Kits)

Step 16

Step 17

Step 18

Remove the Microvalve Seat.

When reassembling the Mi-
crovalve Seat tighten to 15-20
In.- lbs. (1.68– 2.24 N-m)

Using the 5mm Hex Key
Wrench remove the five (5)
SHCS and detach the Top
Valve Plate from the Valve
Manifold.

Top Valve Plate

Valve Manifold

Five (5) SHCS

Tighten to 10-15 In.-Lbs.
(1.23-1.68 N-m)