MAINTENANCE DISASSEMBLY PROCEDURES
(For Robot/Machine Mount Kits)
Step 16
Step 17
Step 18
Remove the Microvalve Seat.
When reassembling the Mi-
crovalve Seat tighten to 15-20
In.- lbs. (1.68– 2.24 N-m)
Using the 5mm Hex Key
Wrench remove the five (5)
SHCS and detach the Top
Valve Plate from the Valve
Manifold.
Top Valve Plate
Valve Manifold
Five (5) SHCS
Tighten to 10-15 In.-Lbs.
(1.23-1.68 N-m)