Aerobell 168 - Maintenance
83
LN-9270-12.3
MAINTENANCE DISASSEMBLY PROCEDURES
(For Robot/Machine Mount Kits)
Step 8
Step 9
Step 10
Remove the plastic SHCS from
the Valve Manifold using the
5/16” (8mm) Hex Key Wrench .
Remove the plastic Wash Cup
Y Fitting from the Valve Mani-
fold by hand, no wrench re-
quired.
Remove the plastic Fluid Tube
Fitting and Fluid Tube Coil from
the Valve Manifold using the
Adjustable Wrench.