Aerobell 168 - Maintenance

77

LN-9270-12.3

MAINTENANCE DISASSEMBLY PROCEDURES

Step 21

Locate the Fluid Tube and Fluid
Tube Retainer.

Step 22

Remove the Fluid Tube Retainer
using the opposite end of the
Fluid Tip/Tube Removal Tool
(A11229-00).

When re-installing, tighten to 65-
75 In.-Lbs. (7.64-8.42 N-m)