Chapter 5. option – IAI America S-SEL-E User Manual

Page 241

Advertising
background image

Page 236

Chapter 5.

Option

(3) Error

Errors will be checked after the SAVE LOAD buttons are pressed.

1)

Communication Error
Indicates an abnormality in the communication circuit. Both lamps (SAVE LOAD) blink approximately every
second. The cable should be inspected.

2)

Write-in Error
The SAVE lamp blinks approximately every second. The Flash Memory Card itself may be the problem. The Flash
Memory Card should be replaced.

3)

No Card Error
This error occurs when the SAVE or LOAD operation is tried without a Flash Memory Card. The SAVE or LOAD
lamp blinks approximately every 0.5 second. A Flash Memory Card must be inserted.

4)

Releasing Error
To reset back to the initial status, press either the SAVE or the LOAD Button.

(4) Specifications

1)

Flash Memory Card

Description

M em ory Type

FLASH-EPROM

Memory Capacity

FLASH512 512Bytes

External Dimensions

85.6±0.2 x 54.0±0.1 x 33±0.1(mm)

Connector

Two piece (JEIDA Specification)

Pitch 1.27mm 68 pins (2 rows)

Applicable Specification

JEIDA/PCMCIA (Direct bus method)

Data Bit Length

8 bit/16 bit

Power Supply Voltage

+5V±5% (MAX 6V)

Weight

50g(MAX)

Advertising
This manual is related to the following products: