background image

Page 250

*Supplement

6.

Emergency Stop

For the Super SEL Controller Type E·G, the Pin 2B and 0V must be short-circuited (because of the B contact point), otherwise,
an Emergency Stop will occur. To release the Emergency Stop for testing first, remove the front cover and short-circuit the
ST1 jumper post with a jumper pin at the bottom of CPU UNIT or CPU SERVO UNIT.

The Emergency Stop operation can be controlled via the teaching pendant while it is being tested.
Note: Please make sure to take off the jumper pin after testing so that the Emergency Stop can operate.

1)

A jumper post (ST1) is placed at the bottom of CPU UNIT or CPU SERVO UNIT.

2)

To release the Emergency Stop, short-circuit the jumper post (ST1) by inserting a jumper pin. After the test, please make
sure to take the jumper pin out again.