Controller Power ON
Ready (301) ON
Program No. Input
External Start (000) Input
Selected Program No. will start.
Chapter 2. Operation
No
○○
Program No. will be displayed on the front panel of the
controller and the [AUTO] mode LED will light up.
Select Program No. from external unit, then input start signal.
Flow Chart
2.
External Start Operating Mode
Timing Chart
Program no.
input
Ready output
External start
input
Power on
T2
T2
T3
T1
T3
T1: Time from ready output ON to start input
Min. 30msec
T2: Time from program No. input to external
start input
Min. 30msec
T3: External start input
Min. 30msec
Yes
Program No. can be input before the Ready prompt.
The BCD code is input at input signal numbers 8~14.