Chapter 1. setting up – IAI America S-SEL-E User Manual

Page 27

Advertising
background image

Page 25

3.

External I/O Specifications

(1) Input

Internal Circuit

Chapter 1.

Setting Up

Time Width while ON

30msec

1)

The power must be supplied externally for the standard I/O board and the expansion I/O board.

2)

For the external circuit connection (no contact point), the leakage per 1point must be kept lower than 1mA when the
switch is OFF.

Guaranteed operation width of the Super SEL Controller input signal

Generally, the input signal operates within 25msec but the guaranteed operation width is 30msec.

Input

Specifications

Point

Dedicated Input...4 Points
User Input....20 Points
Expansion Input (Option)....Max 72 Points

Power Voltage

DC24V +/-20%

Current

7mA/DC24V

ON/OFF Power Voltage

ON....Min DC16.0V OFF....Max DC5.0V

ON/OFF Response Time

ON....Max 20m sec OFF....Max 20m sec

Isolation Method

Photocoupler

External power

Each input

Internal

Circuit

Time Width while OFF

30msec

Advertising