LEESON SM-Plus Series Sub-Micro Inverters User Manual
Page 28

24
13.0
PROGRAMMING THE SM-Plus
™
DRIVE
The drive may be programmed by one of three methods: using the three buttons and 3-digit LED
display on the front of the display, programming the Electronic Programming Module (EPM) using the
optional EPM Programmer, and through a serial link using serial communications. This section describes
programming the drive using the buttons and display, which are shown below:
To enter the PROGRAM mode to access the parameters, press the Mode button. This will
activate the PASSWORD prompt (if the password has not been disabled). The display will read “00” and
the upper right-hand decimal point will be blinking, as shown below:
Press Mode
Display reads “00”
Upper right decimal point blinks
Use the
▲ and ▼ buttons to scroll to the password value (the factory default password is “225”) and
press the Mode button. Once the correct password value is entered, the display will read “P01”, which
indicates that the PROGRAM mode has been accessed at the beginning of the parameter menu (P01 is
the first parameter). This is shown below:
Use
▲ and ▼ to scroll to the
password value
Press Mode to enter password
Parameter menus is accessed at the
first parameter
BUTTONS
Mode
DISPLAY