LEESON SM-Plus Series Sub-Micro Inverters User Manual

Page 28

Advertising
background image

24

13.0

PROGRAMMING THE SM-Plus

DRIVE

The drive may be programmed by one of three methods: using the three buttons and 3-digit LED
display on the front of the display, programming the Electronic Programming Module (EPM) using the
optional EPM Programmer, and through a serial link using serial communications. This section describes
programming the drive using the buttons and display, which are shown below:

To enter the PROGRAM mode to access the parameters, press the Mode button. This will
activate the PASSWORD prompt (if the password has not been disabled). The display will read “00” and
the upper right-hand decimal point will be blinking, as shown below:

Press Mode

Display reads “00”

Upper right decimal point blinks

Use the

▲ and ▼ buttons to scroll to the password value (the factory default password is “225”) and

press the Mode button. Once the correct password value is entered, the display will read “P01”, which
indicates that the PROGRAM mode has been accessed at the beginning of the parameter menu (P01 is
the first parameter). This is shown below:

Use

▲ and ▼ to scroll to the

password value

Press Mode to enter password

Parameter menus is accessed at the
first parameter

BUTTONS

Mode

DISPLAY