14.0

PARAMETER MENU

FACTORY

NO.

PARAMETER NAME

RANGE OF ADJUSTMENT

DEFAULT

(NOTE 1)

01

LINE VOLTAGE

HIGH (01), LOW (02)

HIGH (01)

02

CARRIER FREQUENCY

4kHz (01), 6kHz (02), 8kHz (03), 10 kHz (04)

6 kHz (02)

03

START METHOD

NORMAL (01), START ON POWER UP (02),

NORMAL (01)

START WITH DC BRAKE (03),

AUTO RESTART WITH DC BRAKE (04),

FLYING RESTART 1 (05,) FLYING RESTART 2 (06),

FLYING RESTART 3 (07)

04

STOP METHOD

COAST (01), COAST WITH DC BRAKE (02),

COAST (01)

RAMP (03), RAMP WITH DC BRAKE (04)

05

STANDARD SPEED

KEYPAD (01), PRESET #1 (02),

KEYPAD (01)

SOURCE

0-10 VDC (03), 4-20 mA (04)

06

TB-14 OUTPUT

NONE (01), RUN (02) ,FAULT (03),

NONE (01)

13

TB-15 OUTPUT

INVERSE FAULT (04), FAULT LOCKOUT (05),

NONE (01)

AT SET SPEED (06), ABOVE PRESET #3 (07),

CURRENT LIMIT (08), AUTO SPEED (09),

REVERSE (10)

08

TB-30 OUTPUT

NONE (01), 0-10 VDC FREQ (02),

NONE (01)

2-10 VDC FREQ (03), 0-10 VDC LOAD (04),

2-10 VDC LOAD (05)

09

TB-31 OUTPUT

NONE (01), 0-10 VDC LOAD (02),

NONE (01)

2-10 VDC LOAD (03), DYNAMIC BRAKING (04)

10

TB-13A FUNCTION

NONE (01), 0-10 VDC(02), 4-20mA (03),

NONE (01)

SELECT

PRESET SPEED #1 (04), RUN REVERSE (05),

START REVERSE (06), EXTERNAL FAULT (07),

REMOTE KEYPAD (08), DB FAULT (09),

AUXILIARY STOP (10), ACCEL/DECEL #2 (11)

11

TB-13B FUNCTION

NONE (01), 0-10 VDC (02), 4-20mA (03),

NONE (01)

SELECT

PRESET SPEED #2 (04), DECREASE FREQ (05),

JOG FORWARD (06), JOG REVERSE (07),

AUXILIARY STOP (08)

NOTE 1: Factory defaults are shown for a 60 Hz base frequency. See Parameter 48 for 50 Hz base
frequency.