Parameter menu (m2), Parameter menu, Ttings (chapter 7.3.2), reference – TREND NX Variable Speed Drives User Manual

Page 90: See chapter 7.3.2

Advertising
background image

CONTROL KEYPAD

vacon • 73

24-hour support +358 (0)40 837 1150 • Email: [email protected]

7

7.3.2 Parameter

menu

(M2)

Parameters are the way of conveying the commands of the user to the frequency converter. The parameter
values can be edited by entering the

Parameter Menu

from the

Main Menu

when the location indication M2

is visible on the first line of the display. The value editing procedure is presented in Figure 7-5.

Push the

Menu button right

once to move into the

Parameter Group Menu (G#)

. Locate the parameter

group desired by using the

Browser buttons

and push the

Menu button right

again to enter the group and

its parameters. Use again the

Browser buttons

to find

the parameter

(P#)

you want to edit. From here you

can proceed in two different ways: Pushing the

Menu button right

takes you to the edit mode. As a sign of

this, the parameter value starts to blink. You can now change the value in two different manners:

1

Just set the new desired value with the

Browser buttons

and confirm the change with the

Enter

button

. Consequently, the blinking stops and the new value is visible in the value field.

2

Push the

Menu button right

once again. Now you will be able to edit the value digit by digit. This

editing manner may come in handy, when a relatively greater or smaller value than that on the
display is desired. Confirm the change with the

Enter button

.


The value will not change unless the Enter button is pushed. Pressing the

Menu button left

takes you

back to the previous menu.

Several parameters are locked, i.e. uneditable, when the drive is in RUN status. If you try to change the
value of such a parameter the text

*Locked*

will appear on the display. The frequency converter must be

stopped in order to edit these parameters.
The parameters values can also be locked using the function in menu M6 (see Chapter Parameter lock
(P6.5.2)).

You can return to the

Main menu

anytime by pressing the

Menu button left

for 3 seconds.


The basic application package "All in One+" includes seven applications with different sets of parameters.
You will find the parameter lists in the Application Section of this manual.

Once in the last parameter of a parameter group, you can move directly to the first parameter of that group
by pushing the

Browser button up

.


See the diagram for parameter value change procedure on page 74.