XLT XD-9010B User Manual

Page 16

Advertising
background image


16

Do not use Teflon tape on gas line connections as this can possibly cause gas valve
malfunction or plugging of orifices from shreds of tape. Use of Teflon tape may af-
fect warranty.

FOR EACH OVEN:

Electrical service for Standard Ovens must be 120VAC, 20 A, 60 Hz single phase circuits

with ground.

Electrical service for World Ovens must be 220/230/240VAC, 10 A, 50/60 Hz single phase

circuits with ground.

Electrical service for Australian Ovens must be 220/230/240 VAC, 10 A, 50Hz single

phase and installed in accordance with the latest version of AS/NZS 3000 wiring rules.

A separate circuit breaker must be provided for each oven deck.

Gas and electric connections must be accessible when the ovens are in the installed position.

Electrical plugs and cords must meet all local code requirements.

Gas hose assemblies with quick disconnects for each oven deck will be installed at each valve.

Oven Only Rough-In Specifications

Item # Description

1

1-½ [40] Shut-Off Valve

2

¾ [20] Shut-Off Valve

3

6 [150] Nipple

4

¾ [20] Nipple

5

Reducing Tee

6

Tee

7

Cap

8

Plug

All pipe fittings to be 1-½ [40] minimum
unless noted. NPT & BSP

1

3

2

4

5

6

7

8

3

3

4

CAUTION

NOTE

NOTE: All dimensions in inches [mm].