XLT XD-9010B User Manual

Page 85

Advertising
background image

85

1. Set F001 (Main profile parameters). This will set the output frequency for the exhaust fan.

a. Press & hold the function key until d001 displays.
b. Use the up / down arrows to reach the F001.
c. Press the function key one time.
d. With all of the switches in the off position the display should read 0.0
e. Turn on the oven switches to be set.
f. Press the Up/Down arrows until you reach the desired initial settings.

1832 & 2440

(1) Oven = 20 Hz
(2) Ovens = 30 Hz
(3) Ovens = 40 Hz


3240, 3255, & 3270

(1) Oven = 25 Hz
(2) Ovens= 35 Hz
(3) Ovens = 45 Hz


3855 & 3870

(1) Oven = 30 Hz
(2) Ovens = 40 Hz
(3) Ovens = 50 Hz


g. Press the store button once to store the new setting.

2. Repeat steps d – g for additional settings.
3. When finished turn all of the switches to the off position.
4. Next press the function key & hold until d001 (Display Mode) appears on the display.

a. Press the function one more time 0.0 should display.
b. Press the store button one time to store display mode as the default.

VFD Adjustments

Function

Store

VFD Controller Display

At initial start up, the VFD controller must be set to ensure proper exhaust fan operation.

Advertising