Oven Maintenance

The most critical item to be maintained is the filter on the Flow Path Pressure Generating

fan

.

The filter is held in place by the stainless steel fan guard/filter mount and can be washed sev-

eral times. Regular cleaning of the Flow Path Pressure Generating Fan filter is important to pro-
vide combustion air and to maintain air circulation within the control box. Depending upon store
conditions, this filter should be cleaned weekly or as it gets clogged with dust. After several clean-
ings the filter will need to be replaced.

Contact a factory representative or a local service company to perform all other mainte-

nance and repairs.

NOTICE: If the oven is to be removed from its installed location for cleaning or
servicing, the following procedure is to be implemented:
1. Shut off main manual gas valve.
2. Unplug electric cord.
3. Unplug gas line.
4. Unlock casters.
5. Disconnect restraint.
6. When servicing or cleaning is complete, move oven to original location.
7. Connect restraint.
8. Lock casters.
9. Plug in electric cord.
10. Plug in gas line.
11. Turn manual gas valve on.
12. Follow normal lighting instructions.

Filter