5 chassis installation, 1 airflow, Hassis – IEI Integration WAFER-945GSE2 v1.03 User Manual

Page 85: Nstallation, Table 5-6: lvds voltage selection jumper settings, Figure 4-13, Cn pinouts

Advertising
background image

WAFER-945GSE2 User Manual

Page 68

LCD Voltage Select

Description

Short 1-2

+3.3V LVDS

Default

Short 2-3

+5V LVDS

Table 5-6: LVDS Voltage Selection Jumper Settings

The LVDS Voltage Selection jumper location is shown in Figure 5-7.

Figure 5-7: LVDS Voltage Selection Jumper Pinout Locations

5.5 Chassis Installation

5.5.1 Airflow

WARNING:

Airflow is critical to the cooling of the CPU and other onboard

components. The chassis in which the WAFER-945GSE2 must have

air vents to allow cool air to move into the system and hot air to move

out.

The WAFER-945GSE2 must be installed in a chassis with ventilation holes on the sides

allowing airflow to travel through the heat sink surface. In a system with an individual

Advertising