Proface AGP3500 - 10.4 DIO HMI" User Manual

Page 146

Advertising
background image

Chapter 4 Specifications

4-81

In the case of RS232C

In the case of RS422/RS485

‹Serial Interface (COM2)

This interface is used to connect an RS422/RS485 serial cable. A D-sub 9-pin socket connector is used.

<GP unit side>

Pin

Arrangement

Pin No.

RS232C

Signal Name

Direction

Meaning

1

CD

Input

Carrier Detect

2

RD(RXD)

Input

Receive Data

3

SD(TXD)

Output

Send Data

4

ER(DTR)

Output

Data Terminal Ready

5

SG

-

Signal Ground

6

DR(DSR)

Input

Data Set Ready

7

RS(RTS)

Output

Request to Send

8

CS(CTS)

Input

Send Possible

9

CI(RI)/VCC

Input/-

Called status display

+5V

±

5% Output 0.25A

*1

*1

The RI/VCC selection for Pin #9 is switched via software. The VCC output is not
protected against overcurrent. To prevent damage or a unit malfunction, use only the
rated current.

Shell

FG

-

Frame Ground

(Common with SG)

Pin

Arrangement

Pin No.

RS422/RS485

Signal Name

Direction

Meaning

1

RDA

Input

Receive Data A(+)

2

RDB

Input

Receive Data B(-)

3

SDA

Output

Send Data A(+)

4

ERA

Output

Data Terminal Ready A(+)

5

SG

-

Signal Ground

6

CSB

Input

Send Possible B(-)

7

SDB

Output

Send Data B(-)

8

CSA

Input

Send Possible A(+)

9

ERB

Output

Data Terminal Ready B(-)

Shell

FG

-

Frame Ground

(Common with SG)

Always connect close to the GP unit's COM port when terminating with the termination pins

(TRMRX/TRMTX).

GP Connector

XM3B-0942-502LX <OMRON Co.>

Interfit Bracket

#4-40(UNC)

9

6

5

1

(GP unit side)

9

6

5

1

(GP unit side)

Advertising