Proface AGP3500 - 10.4 DIO HMI" User Manual

Page 182

Advertising
background image

Chapter 8 Installation and Wiring

8-11

When the GP-3500/3600/3700 series is used;

(1)

Confirm that the power cord is unplugged from the power supply.

(2)

Remove the power connector (plug) from the main unit.

(3)

Loosen the three screws in the center of the Power Connector (plug).

(4)

Strip the sheath of the power cord, twist the wire ends, insert them into the bar terminals.

(5)

Fix them with screws.

(6)

Attach the Power Connector (Plug) to the GP and fix it to the GP main unit with right/left tightening

screws.

• Use a flat-blade screwdriver (Size 0.6 X 3.5) to tighten the terminal screws.

The torque required to tighten these screws is 0.5 to 0.6N

•m[5-7Lb•In.].

• Do not solder the cable connection.

Be sure to twist the power cords together, up to the power connector.

+

-

FG

Advertising