Proface AGP3500 - 10.4 DIO HMI" User Manual

Page 85

Advertising
background image

GP3000 Series Hardware Manual

4-20

„AGP-3300

∗/3301∗/3310T/3360T

‹Serial Interfaces (COM1)

This interface is used to connect an RS232C/RS422/RS485

*1

cable. D-sub 9-pin plug connector is used.

<GP unit side>

<Cable side>

In the case of RS232C

In the case of RS422/RS485

*1

Communication method is switched via software.

*2

The RI/VCC selection for Pin #9 is switched via software. The VCC output is not protected against
overcurrent. To prevent damage or a unit malfunction, use only the rated current.

GP Connector

XM2C-0942-502LX <OMRON Co.>

Interfit Bracket

#4-40(UNC)

Recommended Cable Connector

XM2D-0901 <OMRON Co.>

Recommended Cable Cover

XM2S-0913 <OMRON Co.>

Recommended Jack Screw
(#4-40 UNC)

XM2Z-0073 <OMRON Co.>

Pin

Arrangement

Pin No.

RS232C

Signal Name

Direction

Meaning

1

CD

Input

Carrier Detect

2

RD(RXD)

Input

Receive Data

3

SD(TXD)

Output

Send Data

4

ER(DTR)

Output

Data Terminal Ready

5

SG

-

Signal Ground

6

DR(DSR)

Input

Data Set Ready

7

RS(RTS)

Output

Request to Send

8

CS(CTS)

Input

Send Possible

9

CI(RI)/VCC

Input/-

Called status display
+5V

±

5% Output 0.25A

*2

Shell

FG

-

Frame Ground
(Common with SG)

Pin

Arrangement

Pin No.

RS422/RS485

Signal Name

Direction

Meaning

1

RDA

Input

Receive Data A(+)

2

RDB

Input

Receive Data B(-)

3

SDA

Output

Send Data A(+)

4

ERA

Output

Data Terminal Ready A(+)

5

SG

-

Signal Ground

6

CSB

Input

Send Possible B(-)

7

SDB

Output

Send Data B(-)

8

CSA

Input

Send Possible A(+)

9

ERB

Output

Data Terminal Ready B(-)

Shell

FG

-

Frame Ground
(Common with SG)

9

6

5

1

(GP unit side)

9

6

5

1

(GP unit side)

Advertising