C-4 Interfaces

Power Line

The printer provides a +5 volts dc power line to drive the logic of an
external device.

Ground Lines

The printer provides fifteen ground lines consisting of a logic ground,
chassis ground, and thirteen signal return grounds.

Cable/Connector Requirements

The parallel connector must be a 36-pin male plug with a metal backshell
(Amphenol 157-32360 or equivalent). The cable must be shielded with
twisted pair leads (Beldon 9505 or equivalent). The parallel cable must
not exceed 10 feet (3 meters). Figure C-2 shows a typical parallel cable
assembly.

Figure C-2. Parallel Cable Assembly

AMT/IBM

PC WIRING

FROM

TO

SIGNAL

P1-1

P2-1

STROBE–

P1-2

P2-2

DB1

P1-3

P2-3

DB2

P1-4

P2-4

DB3

P1-5

P2-5

DB4

P1-6

P2-6

DB5

P1-7

P2-7

DB6

P1-8

P2-8

DB7

P1-9

P2-9

DB8

P1-10

P2-10

ACK–

P1-11

P2-11

BUSY

P1-12

P2-12

PAPER

P1-13

P2-13

SELIN–

P1-14

P2-14

AUTO FD–

P1-15

P2-32

ERROR–

P1-16

P2-31

IPRIME–

P1-17

P2-36

SELOUT

P1-18

P2-33

GND

P1-19

P2-19

GND

P1-20

P2-21

GND

P1-21

P2-23

GND

P1-22

P2-25

GND

P1-23

P2-27

GND

P1-24

P2-29

GND

P1-25

P2-30

GND

P2

CONNECTOR

SHROUD

CONNECT-

ING

HARDWARE

(2 EA REQ'D)

HEAT-

SHRINK

TUBING

CABLE

SHIELD

UNSHIELDED

WIRES

CABLE

CONNECT-

ING

HARDWARE

(2 EA REQ'D)

BACKSHELL

HEAT-

SHRINK

TUBING

CABLE

CONNECTOR

COPPER

FOIL

RUBBER

BUSHING

MOUNTING

HARDWARE

(2 EA REQ'D)

CONNECT-

ING

HARDWARE

(2 EA REQ'D)

UNSHIELDED

WIRES

DB-25

BACKSHELL

(2-PIECE)

COPPER

FOIL

CABLE SHIELD

P1

User's Guide

C-4 Interfaces

Power Line

The printer provides a +5 volts dc power line to drive the logic of an
external device.

Ground Lines

The printer provides fifteen ground lines consisting of a logic ground,
chassis ground, and thirteen signal return grounds.

Cable/Connector Requirements

The parallel connector must be a 36-pin male plug with a metal backshell
(Amphenol 157-32360 or equivalent). The cable must be shielded with
twisted pair leads (Beldon 9505 or equivalent). The parallel cable must
not exceed 10 feet (3 meters). Figure C-2 shows a typical parallel cable
assembly.

Figure C-2. Parallel Cable Assembly

AMT/IBM

PC WIRING

FROM

TO

SIGNAL

P1-1

P2-1

STROBE–

P1-2

P2-2

DB1

P1-3

P2-3

DB2

P1-4

P2-4

DB3

P1-5

P2-5

DB4

P1-6

P2-6

DB5

P1-7

P2-7

DB6

P1-8

P2-8

DB7

P1-9

P2-9

DB8

P1-10

P2-10

ACK–

P1-11

P2-11

BUSY

P1-12

P2-12

PAPER

P1-13

P2-13

SELIN–

P1-14

P2-14

AUTO FD–

P1-15

P2-32

ERROR–

P1-16

P2-31

IPRIME–

P1-17

P2-36

SELOUT

P1-18

P2-33

GND

P1-19

P2-19

GND

P1-20

P2-21

GND

P1-21

P2-23

GND

P1-22

P2-25

GND

P1-23

P2-27

GND

P1-24

P2-29

GND

P1-25

P2-30

GND

P2

CONNECTOR

SHROUD

CONNECT-

ING

HARDWARE

(2 EA REQ'D)

HEAT-

SHRINK

TUBING

CABLE

SHIELD

UNSHIELDED

WIRES

CABLE

CONNECT-

ING

HARDWARE

(2 EA REQ'D)

BACKSHELL

HEAT-

SHRINK

TUBING

CABLE

CONNECTOR

COPPER

FOIL

RUBBER

BUSHING

MOUNTING

HARDWARE

(2 EA REQ'D)

CONNECT-

ING

HARDWARE

(2 EA REQ'D)

UNSHIELDED

WIRES

DB-25

BACKSHELL

(2-PIECE)

COPPER

FOIL

CABLE SHIELD

P1

Advertising