Job select digital inputs – Watlow CLS200 User Manual
Page 92

Chapter 4: Setup
CLS200 Series User’s Guide
76
Watlow Anafaze
Doc.# 0600-3050-2000
Job Select Digital Inputs
Set the number of job select inputs. The controller uses
these inputs as a binary code that specifies the job number
to run. The number of inputs you choose in this parameter
controls the number of jobs you can select remotely.
If you select NONE, digital inputs do not affect job selection.
Jobs may be loaded and saved using the LOAD SETUP FROM
JOB and SAVE SETUP TO JOB parameters.
Selectable values: 1, 2 or 3 inputs, or NONE. These choices
have the following effect:
Table 4.2
Job Select Inputs
Table 4.3 shows which input states select which jobs. When
nothing is connected, the inputs are all false and job 1 is se-
lected.
Table 4.3
Job Selected for Various Input
States
Setting
Enables
1
Jobs 1-2
2
Jobs 1-4
3
Jobs 1-8
NONE
Disables remote job selection
Digital Input 3 Digital Input 2 Digital Input 1
Job
No.
F
F
F
1
F
F
T
2
F
T
F
3
F
T
T
4
T
F
F
5
T
F
T
6
T
T
F
7
T
T
T
8
ALARM
JOB SELECT
DIG INPUTS? NONE