CPC400 Series User’s Guide

Chapter 5: Menu and Parameter Reference

Doc. 0600-2900-2000

Watlow Anafaze

95

Figure 5.2

Setup Menus and Parameters

Output

Heat output type
Heat cycle time
Heat SDAC signal
Ht SDAC low signal
Ht SDAC hi signal
Heat action
Heat power limit
HtPwr limit time
Sensor fail heat output
Open T/C ht out average
Heat output curve
Cool output type
Cool cycle time
Cool SDAC signal
Cl SDAC low signal
Cl SDAC hi signal
Cool action
Cool power limit
ClPwr limit time
Sensor fail cool output
Open T/C cl out average
Cool output curve

Alarms

Alarm high SP
Alarm high func
Alarm high output
HiDeviation value
HiDeviation func
HiDeviation output
LoDeviation value
LoDeviation func
LoDeviation output
Alarm low SP
Alarm low func
Alarm low output
Alarm hysteresis
Alarm delay

Global setup

Load setup from job
Save setup as job
BCD job load
BCD job load logic
Mode override
Mode override D/I active
Logic program
Power up alarm delay
Power up loop mode
Power up with logic
Keypad lock
TC short alarm
Controller address
Comm baud rate
Comm parity
AC line freq
D/O alarm polarity
CPC4xx Vx.xxX cs=xxxx

Input

Input type
Input units

Input pulse sample

Calibration offset
Reversed T/C detect
Disp format
Input range high
Input high signal
Input range low
Input low signal
Input filter

Channel

Loop name
PV Source

Control

Heat prop band
Heat integral
Heat derivative
Heat manual reset
Heat filter
Cool prop band
Cool integral
Cool derivative
Cool manual reset
Cool filter
Hysteresis
RestoreAuto
Tune band
Tune gain
Overshoot reduction
Control type

Access the setup menus (press and hold for 3 seconds)
Cancel a change without saving.
Escape from a parameter to a menu.
Escape from a menu to the loop display.

PV retrans

Heat output retrans PV
Ht retrans LowPV
Ht retrans HighPV
Cool output retrans PV
Cl retrans LowPV
Cl retrans HighPV

Cascade

Cascade prim loop
Cascade low SP
Cascade hi SP

Ratio

Ratio master loop
Ratio low SP
Ratio high SP
Control ratio
Ratio SP diff

Soft integers

Soft int 1 value
...
Soft int 1100 value

Soft Booleans

Soft Bool 1 value
...
Soft Bool 256 value

I/O tests

Digital inputs
Keypad test
Test D/O 1
...
Test D/O 35

Go to the next or previous menu.
Edit a parameter value.

Save a value and go to the next or previous parameter.

Save a value and go to the next or previous loop.

Navigation for the Setup Menus

,.