<3. Parameter Setting>

3-17

IM 01C25T01-06EN

a. Display Selection

At

Disp select, select the variable that the

parameter Disp Out 1 will display on the integral

indicator.

• Procedure to call up the display

DD and DTM

(excluding EJX_

HART 5[1.2])

[Root Menu] → Detailed setup →

Display condition → Disp select →

EJX_HART 5[1.2]

DTM

Configuration → Local Display →

→ Disp Out 1 to 4 Select desired display from five

kinds of display shown above.

Set Disp Out 2, Disp Out 3 and Disp Out 4 in the

same way if necessary.

In addition to the above item, “Not used” is also

displayed as a selection item.
b. Cyclic Display
Up to four displays can be displayed cyclically in the

order of the parameter number.
c. Display Resolution
User can change the position of decimal point

which is shown on the integral indicator.

• Procedure to call up the display for PV %

DD and DTM

(excluding EJX_

HART 5[1.2])

[Root Menu] → Detailed setup

→ Display condition → P disp

condition →

EJX_HART 5[1.2]

DTM

Configuration → Local Display →

→ Disp Pres %

Reso

Select the decimal point position of

pressure

Normal: Display one digit below

the decimal point

High Resolution: Display two digits

below the decimal point

• Procedure to call up the display for Pres and SP

DD and DTM

(excluding EJX_

HART 5[1.2])

[Root Menu] → Detailed setup

→ Display condition →

EJX_HART 5[1.2]

DTM

Configuration → Local Display

(→ P disp condition)

→ Pres disp point

Select the decimal point position

of differential pressure (0, 1, 2,

3 or 4)

(→ SP disp condition)

→ SP disp point

Select the decimal point position

of static pressure (0, 1, 2, 3 or 4)

d. User Setting of Engineering Unit and Scale

Setting by DD and DTM (EJX HART 5 DTM

based on FDT1.2)

Engr disp range parameters allow the engineering

unit and scale to be displayed. At

Set Engr Unit,

the following engineering units can be selected from

a list.

• Procedure to call up the display

DD and DTM

(excluding EJX_

HART 5[1.2])

[Root Menu] → Detailed setup

→ Display condition → Engr disp

range

→ Set Engr Unit Select the engineering unit
→ Engr LRV

Lower range value

→ Engr URV

Upper range value

→ Engr exp

Exponents for user scale display

→ Engr point

Decimal point position for user scale

display (0, 1, 2, 3 or 4)

Select the engineering unit from the list. Available

units are shown below

kPa

MPa

mbar

bar

psi

psia

mmH

2

O

mmHg

mmHgA

mmAq

mmWG

Torr

inH

2

O

inHg

inHgA

ftH

2

O

gf/cm

2

kgf/cm

2

kg/cm

2

G

kg/cm

2

A

atm

kg/h

t/h

m

3

/h

m

3

/min

l/h

l/min

kl/h

kl/min

Nl/h

Nl/min

Nm

3

/h

Nm

3

/min

ACFH

ACFM

SCFH

SCFM

GPH

GPM

m

mm

in

ft

kg/m

3

g/cm

3

At

Modify Engr Unit parameter, user can set your

own unit also.

Up to eight alphanumeric characters, spaces or one

slashe (/) can be input at

Modify Engr Unit; only

the first six are displayed on the integral indicator.

• Procedure to call up the display

DD and DTM

(excluding EJX_

HART 5[1.2])

[Root Menu] → Detailed setup

→ Display condition → Engr disp

range →

→ Modify Engr

Unit

Set your own unit

Note that following symbols are not available:

# % & < > . * : + - , ’ ( )

The integral indicator shows “-- -- -- -- -- --” when

these symbols or more than two slashes are

entered.