Yokogawa EJA440E User Manual

Page 81

Advertising
background image

<5. Parameter Summary>

5-3

IM 01C25T01-06EN

Function

Label

Item

Contents

Default value Handling

*

1

Diag Lim

Lim fDPmax

Upper limit for Ratio fDP

Refer to Table 4.2.3

WG

Lim fDPmin

Lower limit for Ratio fDP

Refer to Table 4.2.3

WG

Lim fSPlmax

Upper limit for Ratio fSPl

Refer to Table 4.2.3

WG

Lim fSPlmin

Lower limit for Ratio fSPl

Refer to Table 4.2.3

WG

Lim fSPhmax

Upper limit for Ratio fSPh

Refer to Table 4.2.3

WG

Lim fSPhmin

Lower limit for Ratio fSPh

Refer to Table 4.2.3

WG

Lim BlkFmax

Upper limit for BlkF

Refer to Table 4.2.3

WG

Lim BlkFmin

Lower limit for BlkF

Refer to Table 4.2.3

WG

Lim DPAvgmax

Upper limit for DPAvg

Refer to Table 4.2.3

WG

Lim DPAvgmin

Lower limit for DPAvg

Refer to Table 4.2.3

WG

Diag Mode

Diag Mode

ILBD operation mode

Stop, Calculation, or

Reference

WG

Diag Option

Diag Option

Alarm masking

WG

Diag Output

Diag Out Option

Output mode of 4-20mA when

an advanced diagnostic alarm is

generated

Off, Burnout, or Fall back

Off

WG

Diag Fixed Out Val 4-20 mA output when an advanced

diagnostic alarm is generated

3.6000 to 21.6000 mA

21.6 mA

WG

Diag Period

Diag Period

Sampling period per one Diag count

180 sec

WG

Diag

Reference

Diag Description

Memo field

32 alphanumerics

WG

Ref fDP

Reference value of fDP

WG

Ref fDP Status

Status of Reference fDP

RG

Ref fSPl

Reference value of fSPl

WG

Ref fSPl Status

Status of Reference fSPl

RG

Ref fSPh

Reference value of fSPh

WG

Ref fSPh Status

Status of Reference fSPh

RG

Ref BlkF

Reference value of BlkF

WG

Ref BlkF Status

Status of Reference BlkF

RG

Ref DPAvg

Reference value of DPAvg

WG

Ref DPAvg Status

Status of Reference DPAvg

RG

Diag Ref Lim Ref Lim fDPmin

Lower limit of fDP

7.0E-10

WG

Ref Lim fSPmin

Lower limit of fSPl and fSPh

1.0E-10

WG

Ref Lim BlkFmax

Upper limit of BlkF

0.5

WG

Diag Supp

Count

Diag Supp Count

Detection count to generate an

alarm

WG

Diag Variables Ratio fDP

SQRT (fDP/Ref fDP).

RG

Ratio fDP Status

Status of Ratio fDP

RG

Ratio fSPl

SQRT (fSPl/Ref fSPl).

RG

Ratio fSPl Status

Status of Ratio fSPl

RG

Ratio fSPh

SQRT (fSPh/Ref fSPh).

RG

Ratio fSPh Status

Status of Ratio fSPh

RG

BlkF

Blockage degree characterized in

comparison of high-pressure side

and low-pressure side pressure

fluctuation values

RG

BlkF Status

Status of BlkF

RG

DPAvg

Ratio of the average of differential

pressure/pressure to the maximum

span of an EJX transmitter.

RG

DPAvg Status

Status of DPAvg

RG

CRatio fDP

Compensated fDP

RG

CRatio fDP Status

Status of CRatio fDP

RG

NRatio fDP

Non-compensated fDP

RG

NRatio fDP Status

Status of NRatio fDP

RG

*1:

Handling:

R=Read only, W=Read & Write, M=Method, A=Applicable for option code AL, G=Applicable for option code DG6,

D=Applicable for differential pressure transmitters. Do not change these parameters for pressure transmitters.

*2:

Max three Burst Messages (Burst Message 1, Burst Message 2, Burst Message 3)

*3:

The default value shows MWP (Maximum working pressure) of the capsule.

Since the working pressure limit varies according to the Model, refer to the General Specifications section in each user’s manual.

Advertising
This manual is related to the following products: