MAINTENANCE

IM 1F2B4-01-YIA
Page 74

4.1.15 Using the upload/download feature

The upload/download feature of the BT100/200 allows for one meter to be configured for an application
and then be copied to other meters with a minimum of key strokes. Note: Only the parameters in menu B
and C will be transferred via the upload/download procedure. The tag number will not be transferred.

To UPLOAD a configuration:

BT200 handheld terminal

BT100 handheld terminal

1.

Attach the handheld terminal leads to the appropriate
instrument.

2.

Using the BT100/200 set up the parameters in the YEWFLO as
required, or go to step 3 if the YEWFLO is already setup.

3.

From the menu screen, press
F4, (ESC) soft key to go to
the Function menu. Scroll
down and select the UPLOAD TO
HHT choice.

From any menu or parameter
display, press the UPLD
key.

4.

Press ENTER twice to
begin the upload.

Press the ENT twice to begin
the upload.

5.

Do not disconnect the leads until the UPLOAD DONE or upload
COMPLETE message is displayed. Note: Only one configuration at
a time may be stored in either the BT100 or BT200.

To DOWNLOAD a stored configuration:

BT200 handheld terminal

BT100 handheld terminal

1.

Attach the handheld terminal leads to the appropriate
instrument.

2.

From the menu screen, press
F4, (ESC) soft key to go to
the Function menu. Scroll
down and select the DOWNLOAD
TO INST choice.

From any menu or parameter
display, press the DNLD
key.

Press ENTER twice to
begin the download.

Press ENT twice to begin the
download.

3.

Do not disconnect the leads until the Download DONE or
DOWNLOAD COMPLETE message is displayed. Note: This same
configuration may be downloaded to as many YEWFLO meters
as are required.

Note: Only the parameters in menu B and C will be transferred via the upload/download procedure. The
tag number will not be transferred.