Troubleshooting – Yokogawa digitalYEWFLO (DY) User Manual

Page 98

Advertising
background image

TROUBLESHOOTING

IM 1F2B4-01-YIA

Page 93

Q

n

Volumetric flow at standard conditions

Q

f

Volumetric flow at operating conditions

ρ

f

Density at operating conditions (B14 or B19)

h

f

Specific enthalpy (kcal/kg), (Btu/lb) (B20)

T

n

Standard temperature

P

f

Operating pressure (kg/cm

2

abs), (psia)

P

n

Standard pressure (kg/cm

2

abs), (psia) (B27)

K

Deviation factor for gas (B28)

ρ

n

Density at standard temperature and standard pressure (kg/Nm

3

), (lb/scf)

F

S

Flowrate span (B52)

T

E

Total rate (C01)

D

Internal diameter (m), (inch) (B03)

µ

viscosity (cP)

ρ

f

Density at operating conditions (kg/m

3

), (lb/ft

3

)

•Conversion factors
Unit conversion factors:

U

k(kg)

, U

k

(cal), U

k

(Nm

3

), U

k

(m

3

), U

k

(lb),

U

k

(Btu), U

k

(scf), U

k

(acf)

Kilogram conversion factors:

U

k(kg)

= 1 for a kilogram

U

k(kg)

= 0.001 for a metric ton

Actual cubic feet conversion factors:

U

k(acf)

= 1 for acf

U

k(acf)

= 7.481 for a gallon

K-factor conversion factors:

U

kt

1/1000 (litre m

3

)

U

kt

0.3369 (USgal to actual cubic feet)

User's unit conversion factor

U

k

= U

k

(user) (C09)

For more information, refer to How to setup user defined units in the How to section of this manual.

6.3.2

Flow conversion factor (U

k

)

Flow conversion factor U

k

is obtained from the following computation depending on the fluid selected

(B04) and the flow units.

•Steam
M (Mass flowrate)

U

k

=

ρ

f

* U

k

(kg)

U

k

=

ρ

f

* U

k

(lb)

H (Heat quantity)

U

k

= U

ρ

f

* h

f

*Uh

f

* U

k

(kg)

U

k

= U

ρ

f

* h

f

*Uh

f

* U

k

(lb)

Qf (Flowrate at operation)

U

k

= U

k

(m

3

)

U

k

= U

k

(acf)

•Gas
Qn (Flowrate at STP)

U

k

= P

f

* T

n

+ 273.15 * 1 * U

k

(Nm

3

)

P

n

T

f

+ 273.15 K

M (Mass flowrate)

U

k

=

ρ

f

* U

ρ

f

* U

k

(kg)

U

k

=

ρ

f

* U

ρ

f

* U

k

(lb)

Advertising