<APPENDICES>

APPENDICES

Appendix A Glossary and Acronyms

TA01-1.EPS

FAS

Fieldbus Access Sublayer

FMS

Fieldbus Messaging Service

MIB

Management Information Base

SMIB

System Management Information Base

MAN

Manual mode

RCAS

Remote Cascade mode

LO

Local Override mode

IMan

Initialization manual mode

ROUT

Remote output mode

Cas

Cascade mode

AUTO

Automatic mode

OOS

Out of Service mode

Algorithm

A set of rules that control the operation of an object through software.

Closed

The valve position in which the flow is minimum or zero. See tight shutoff.

AO

Analog Output block

Basic Device

A Basic Device is any device not having the capability to control communications on an H1 fieldbus
segment.

0xf7

See hexadecimal. This is the number 247 represented in hexadecimal notation. The 0x preamble
indicates hexadecimal notation.

1.#INF

This is the representation of infinity as expressed in IEEE 754 floating point arithmetic. It is used in
fieldbus devices to set a parameter to a value that does not interfere with operation, such as for a
limit, for example.

ATC Air to close

The combination of a single acting actuator and the control valve where the valve is closed when air
pressure is applied to the actuator. A spring opens the valve when air pressure is removed.

Capabilities File

A Capabilities File describes the communication objects in a fieldbus device. A configuration device
can use Device Description (DD) Files and Capabilities Files to configure a fieldbus system without
having the fieldbus devices online.

Characteristic

The positioner input setpoint command may be selectively modified to provide a desired relationship
between setpoint and valve position. In the valve, the relationship between stroke and Cv is also
called valve inherent characteristic. It is often adjusted by design, to equal percentage, for example.
The positioner characteristic is applied to modify the setpoint to travel relationship of the actuator.
The characteristic of the positioner should be chosen to compliment the valve. If the valve is equal
percentage, the positioner should be set to linear. If a linear valve is installed the positioner may be
set to an equal percentage characteristic to improve flow control. Local display can be used to select
the custom characteristic, but cannot adjust the points.

ATO Air to open

The combination of a single acting actuator and the control valve where the valve is open when air
pressure is applied to the actuator. A spring closes the valve when air pressure is removed.

Communications Stack

A Communications Stack is device communications software which provides encoding and decoding
of User Layer messages, deterministic control of message transmission, and message transfer.

Compliance voltage

The voltage that must be available at the control system output in order to drive the control current
through all the resistive devices in series with it.