8

snSwIfInfoPortQos
brcdIp.1.1.3.3.5.1.12
Syntax: Integer

Read-write

Indicates the Quality of Service (QoS) level selected for the port:

low(0) – Low priority

high(1) – High priority

level0(0)

level1(1)

level2(2)

level3(3)

level4(4)

level5(5)

level6(6)

level7(7)

snSwIfInfoPhysAddress
brcdIp.1.1.3.3.5.1.13
Syntax: Physical address

Read-only

Shows the physical address of the port.

snSwIfLockAddressCount
brcdIp.1.1.3.3.5.1.14
Syntax: Integer

Read-write

Indicates the number of source MAC addresses that are allowed on the
interface.
Valid values: 0 – 2048. The value 0 means an unlimited number of
addresses are allowed.
Default: 8

snSwIfStpPortEnable
brcdIp.1.1.3.3.5.1.15
Syntax: Integer

Read-write

Indicates if STP is enabled for the port:

disabled(0)

enabled(1)

snSwIfDhcpGateListId
brcdIp.1.1.3.3.5.1.16
Syntax: Integer

Read-write

Specifies the ID for a DHCP gateway list entry relative to this switch port.
Valid values: 0 – 32. A value of 0 means that the ID is unassigned.

snSwIfName
brcdIp.1.1.3.3.5.1.17
Syntax: Display string

Read-write

Indicates the port name or description. This description may have been
entered using the CLI.
Valid values: Up to 32 characters for most devices. Up to 255 characters
for Brocade MLXe devices and other Brocade NetIron devices.

snSwIfDescr
brcdIp.1.1.3.3.5.1.18
Syntax: Display string

Read-only

A textual string containing the slot or port information about the
interface.

snSwIfInfoAutoNegotiate
brcdIp.1.1.3.3.5.1.19
Syntax: Integer

Read-write

Applies only to Gigabit Ethernet ports.
Indicates if auto-negotiation mode is enabled on the port:

disabled(0) – The port will be placed in non-negotiation mode.

enabled(1) – The port will start auto-negotiation indefinitely until it
succeeds.

negFullAuto(2) – The port will start with auto-negotiation. If the
negotiation fails, then it will automatically switch to non-negotiation
mode. This option is not supported in stackable products with
Gigabit Ethernet ports.

global(3) – The port negotiation mode follows the value of
snSwGlobalAutoNegotiate.

other(4) – Non-Gigabit Ethernet port returns this value.

Default: global(3)

snSwIfInfoFlowControl
brcdIp.1.1.3.3.5.1.20
Syntax: Integer

Read-write

Indicates if port flow control is enabled:

disable(0)

enable(1)

Default: enabled(1)