background image

Part No. 4801-5093 Rev 4-08

Unitized System

Page 26





































Connect In-Line Pump to
Spray Line

NOTE: The total vertical height of pipe sections in
the following instructions must reach from In-Line
Pump to level of spray line. Adjust lengths of pipe
sections as required for proper height.

1. Attach PVC pipe section to outlet of In-Line Pump

with union.

2. Attach 1" (2.5 cm) dia. PVC extension with ball

valve to open end of pipe. This is used as an exhaust
port to drain system.

3. Extend PVC pipe section with ball valve to height of

spray line. Attach 90

° elbow at top of pipe section.

4. Add PVC pipe section with union to connect elbow

to spray line as shown in diagram.

5. Slide In-Line Pump cover over the In-Line Pump

and fasten with screws to the wood platform.

IMPORTANT! Refer to Diagram on page 27

for additional spray line
connections for systems
greater than 80 ft. (24.4m)

Union

Elbow

Strainer Basket

NOTE: Pump cover

not Shown for
clarity

IMPORTANT WATER FLOW INFORMATION!

The water flow can be adjusted using ball valves (flow regulators)
to ensure adequate water flow through system. The pump can
supply adequate pressure to systems up to 80 feet in length.
Lengths up to 120 feet can be accomplished when the Center-
Mount System is installed.