Hired-Hand Mega-Cool rev 4-08 User Manual

Page 56

Advertising
background image

Part No. 4801-5093 Rev 4-08

Unitized System

Page 56

Detail F – Left Limit Switch Roller

Detail G – Manually Open Curtain

Limit
Switch
Roller

5. When the three switch grooves [21] are in line, the three Adjusting Screws in the

adjusting rings [9, 11, 13] are also in one line. Tighten the screws in the setting rings
[9, 11, 13] using a 1.5 mm hex wrench. Torque to 1.3 to 1.5 in.-lb.


6. Open the Curtain. See Detail G.









7. Turn the 3 Setting Rings of the Right Limit Switch like in Step 4.

8. Tighten screws in setting rings [15, 17, 19] to 1.3 to 1.5 in.-lb.

9. Verify the operation of the Limit Switch Settings by operating the curtain from the

controller.

10. Replace the tools in the Vinyl Seal and replace the Limit Switch Cover [6] and Seal [30].
























































Setting

Rings

Hex

Adjusting

Screws

Curtain Opens

Advertising